Integrated security system “Antel” ensures the safety of medium and small by the scale of objects, such as residential and office buildings, institutions, enterprises, public places citizens, etc.
ISS "Antel" integrates the functions of security and fire alarms, access control and management, control of external devices, as well as two-way addressable voice communication and notification.
More details
Need some advice?
Contact the specialists
our support team
right now!
Compared to existing ISS analogues on the market
"Antel"
has a number of unique advantages in terms of high
speed and ensuring global work tactics
ACS
in real time (global anti-passback and zonal
control),
capabilities of addressable voice communication and notification and encryption
communications
128-bit key according to the GOST 28147-89 algorithm.
ISS "Antel" is a software and hardware complex,
designed to ensure security and regime
work
protected objects.
Distributed tree architecture based on combination of a common bus and RS-485 interface branches. Possibility of branching and looping of communication lines and nutrition
Wide range of instruments and equipment
Fully featured system (hardware and software) integration of OPS and ACS functions on all levels – control panels, remote control management and automated workplace
Fully functional system integration Fire alarm system, access control system and closed circuit television at the workstation level. Automated search for records and viewing video archive using an event log in OPS and ACS subsystems
Availability of an interactive electronic map of the protected object with the ability to display locations and the state of technical security equipment. Interactive object state management;
Description of the structure and tactics of operation of the protected object and all ongoing events in generally accepted terms "section" and "zone"
Expanded range of types of security zones: security, alarm, fire, access point, video surveillance (when working with an automated workplace), voice communication (when working with an automated workplace), alerts (when working with an automated workplace), management
A unified format of control commands and display of events for all subsystems (OPS, ACS, etc.) in generally accepted terms “section” and “zone”
Ability to create custom control commands
Administration of user rights through settings of access levels and groups (accepting, disabling, access)
Possibility of photo identification of users (when working with automated workstations)
Possibility of scaling, optimization of the composition and structure of the system for both small and large large objects
Compliance of all ACS parameters with the requirements for universal systems of the 3rd (highest) class according to GOST R51241-2008 classification;
Guaranteed time to provide access is 0.5 s, regardless of the number of access points in system
Local and global pass-through control
Local and global area control, route control
Managing the functions of fire alarm system and access control system using the same electronic identifier (Proximity card or Touch memory key);
Ability to control the operation of external devices
Imitation resistance and cryptographic resistance, message encryption with a 128-bit key according to the GOST 28147-89 algorithm
Possibility of autonomous operation of control panels
Remote (centralized and distributed) adaptive redundant power supply of peripheral devices in a wide range of permissible supply voltages (18÷56 V). Connectivity additional power supplies
Advanced diagnostics of power supplies: monitoring of 220 V mains voltage, battery voltage battery (battery), battery charge current (if network is available), secondary supply voltage
Possibility of powering detectors, sirens and actuators from on-site devices via protected, monitored power lines
Possibility of automatically turning off power to detectors when removed
Easy installation due to the presence of dual terminals for communication and power lines, no need use of additional switching devices
Possibility of remote configuration of devices without disrupting the functionality of the entire system
Possibility of remote reprogramming of alarm loop alarm thresholds without disruption of the entire system
Self-diagnosis of devices in real time. Automatic switching of devices to mode programming when errors are detected in the firmware
Keeping a log (protocol) of events
ISS “Antel” solves the problems of a number of functional security systems:
fire alarm systems
access control and management systems
actuator control systems
operational voice communication systems
warning systems
diagnostic systems
uninterruptible power systems
Various arming and disarming tactics: automated using electronic identifiers and keyboards, automatic according to schedule and according to the absence of users in the section, decentralized and centralized
Protection against false alarms due to high voltage in alarm loops (24 V), digital filtering AC network signals, impulse noise, electrostatic influences and other electromagnetic interference
Possibility of precise adjustment of loop response thresholds, which allows the use of any types detectors, simplifies installation and commissioning, and also further reduces the likelihood of false activations
Possibility of automatically resetting alarms from loop-powered detectors when armed
Independent control in one loop of the alarm contact and the sensor blocking contact
Duress withdrawal detection
Mechanism for setting arming/disarming powers by programming access levels and schedules work
Connecting smoke, heat, combined fire detectors
Recognition of double alarms of detectors in one alarm loop
Protection against false alarms by automatically resetting loop-powered detectors
Possibility of precise adjustment of thresholds for changing alarm loops
Control by Touch Memory keys, Proximity cards and/or PIN code
Centralized and distributed (local) storage of access keys
Local and global pass-through control
Local and global area control, route control
Duress detection
Detection of code guessing attempts during double identification
Administration of user arming/disarming and access permissions for staff and visitors by programming access levels and work schedules
“Eternal schedule” – automatic cyclic calculation of schedules and daily schedules providing access to user groups without expiration dates
Setting up exception schedules
Priority work schedules (work by order)
Automatic change of access mode depending on the state of fire alarm loops and user rights
Monitoring the status of the locking device (lock)
Monitoring the status of the emergency exit button
High performance and short information delivery time (0.5 s)
Encryption of communication with a 128-bit key according to the GOST 28147-89 algorithm
Linear, radial, tree and ring topologies
Possibility of looping communication and power lines with provision of short-circuit cutting function plots
Wide range of supply voltages (18÷56 V)
Possibility of remote adaptive redundant power supply of devices, including ACS with shut-off devices (locks)
The presence in the devices of individual power lines for each AL of four-wire detectors with short circuit protection
Possibility of remote reprogramming of devices
Possibility of remote reconfiguration of devices
Remote diagnostics and self-diagnosis of devices
Possibility of working together with the integrated security complex “Pakhra”
| Devices connected to the RS-485 interface communication line | up to 240 |
| Security zones | before 1920 |
| Security zones grouped into sections | before 1920 |
| Entry/exit access points | up to 240 |
| Passage access points | up to 480 |
| Guaranteed access time, s | 0,5 |
| Outputs for controlling external devices | until 1440 |
| Users | up to 8,000 |
| Event log capacity | 32 000 |
| Length of RS-485 interface communication line, m | up to 700 |
| Speed in the communication line of the RS-485 interface, kBaud | + |
| Radio frequency range for receiving notifications from site equipment, MHz | 230 |
| RS-485 communication line repeaters | up to 10 |
| Ringing and branching of the communication line of the RS-485 interface | + |
From March 21 to March 24, 2017, a training gathering of technical equipment specialists was held in Syktyvkar
protection of the Northwestern District of the National Guard troops. At the invitation of the district command in
It was attended by specialists from the ASB group of companies.
The training program included theoretical and practical classes to study the fundamentals
operation of integrated security systems “Pakhra” and “Antel”.
Based on the results of training sessions for specialists of the ASB group of companies from the command side
The northwestern district of the National Guard troops was thanked.
ASB-SERVICE LLC completed a range of works to ensure comprehensive security for five departments
security of the FGKU UVO Ministry of Internal Affairs of Russia RSO-Alania.
The functions of fire alarm system, access control system, mobile phone system, notification and voice communication, and number recognition systems are implemented
motor transport.
The project was implemented using ISC "Pakhra" and ISS "Antel" produced by LLC NPP "ASB "Record".
ASB-SERVICE LLC created and put into operation an integrated shopping security complex
center in the village Dubki, Odintsovo district, Moscow region (micro-district “Hussar Ballad”). shopping center
is a six-story building with parking located on the upper floors.
The security complex was built using equipment ISC "Pakhra" and ISS "Antel"
produced by LLC NPP "ASB "Record".
To ensure the security of the facility, 8 access control and control points were organized,
2 video intercoms installed, 72 high-definition video cameras connected, mounted about
240 detectors of different operating principles, as well as voice communication and notification
sedentary population groups with a security point in five security zones.
In addition, paid parking is provided, consisting of two specialized
automatic barriers, payment terminal and automated workstation
cashier operator.
The MIPS 2012 exhibition has ended. We thank our colleagues, partners and all the guests who visited our
stand, for the interest shown in our products.
At our stand we presented equipment for solving all problems related to complex
security of various objects and perimeters of any length.
In particular, new developments of the integrated system were demonstrated at the exhibition
security ISS "Antel", as well as the CCTV system "Antel-Video".
The MIPS 2011 exhibition has ended.
The ASB group of companies thanks its colleagues, partners and all visitors to our
stand that showed
interest in the company's products.
Integrated security systems ISC “Pakhra”, ISS were presented at our stand
"Antel", radio notification transmission systems "Radioset" and "Struna-M", peripheral
equipment.
The operation of software for automated workstations of centralized security consoles was demonstrated.
The MIPS 2010 exhibition has ended. The ASB group of companies thanks all visitors to our stand,
who showed interest in the company's products.
Integrated security systems ISC “Pakhra”, ISS were presented at our stand
"Antel", radio notification transmission systems "Radioset" and "Struna-M", peripheral
equipment.
The operation of the software for workstations was demonstrated.
Dear colleagues, partners!
The ASB group of companies invites you to visit our stand at the main technology event of the year
security – MIPS 2011.
The exhibition will be held from April 26 to 29 at the Expocenter on Krasnaya Presnya Exhibition Complex.
Layout of the ASB company stand in Pavilion No. 1
AT OUR STAND WILL BE PRESENTED:
• new features of the integrated security complex (ISC) “Pakhra”, as well as
integrated
security systems (ISS) “Antel” to ensure comprehensive security
geographically distributed objects and perimeters of any size;
• radio system for transmitting notifications of a new generation with a capacity of up to 20,480 objects RSPIS
"Radioset";
• a set of automation software CCO, providing the ability to create
geographically distributed multifunctional monitoring centers (MCM) and information
ensuring the activities of the response and maintenance services included in the MMC.
To receive a free ticket to the exhibition, the organizers recommend completing the electronic
registration.
This procedure will significantly reduce the time of on-site registration activities.
Filling out a form when receiving a free ticket is a mandatory procedure for
everyone.
• Fill out the registration form in advance;
• Print out the ticket and take it with you to the Exhibition;
• Proceed to the Express Check-in counter following the directions on your ticket.
We hope that this event will be interesting and effective for you!
Sincerely, the team of the Group of Companies "ASB"!